{"product_id":"ruijie-networks-rg-cs83-48gt4xs-pd-network-switch-managed-l3-gigabit-ethernet-101001000-power-over-ethernet-poe-1u-grey-rg-cs83-48gt4xs-pd","title":"Ruijie Networks RG-CS83-48GT4XS-PD network switch Managed L3 Gigabit Ethernet (10\/100\/1000) Power over Ethernet (PoE) 1U Grey","description":"\u003cstyle\u003etable.generic tr th {background: #eee;}\u003c\/style\u003eRG-CS83-48GT4XS-PD 48-Port GE Electrical Layer 3 Managed Access Switch with PoE+, Four 10G Uplink Ports\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e48 x GE Ethernet ports and 4 x 10GE uplink optical ports\u003c\/li\u003e\n\u003cli\u003eIEEE 802.3af and IEEE 802.3at compliant, PoE+ supported\u003c\/li\u003e\n\u003cli\u003eVSU, Realizing Flexible Networking and High Performance\u003c\/li\u003e\n\u003cli\u003eMultiple management modes, allowing simplified and easy network maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDescription\u003c\/h2\u003e\u003cb\u003eLayer 3 Access Switch for 10G Uplink RG-CS83-48GT4XS-PD\u003c\/b\u003e\u003cbr\u003eFull-gigabit access switch for large-sized enterprise and campus LANs, with four 10G uplink optical ports for high-speed data transmission\u003cbr\u003e48 x 1000 Mbps Ethernet ports with auto-negotiation, PoE+ supported, providing high-speed network experience for short-distance services\u003cbr\u003e\u003cbr\u003e\u003cb\u003eCompact switch, easy to adapt to a variety of environments\u003c\/b\u003e\u003cbr\u003eThe switch features user-friendly installation.The full range of unified 220mm sizes can be adapted to a variety of environments.It can be mounted on a wall, on a desk or under a desk.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eDual-boot at the hardware level, Offering Carrier-class Reliability\u003c\/b\u003e\u003cbr\u003eTwo flash chips used to store boot software to achieve hardware-level boot redundancy,\u003cbr\u003eavoiding switch boot failures due to flash chip faults\u003cbr\u003e\u003cbr\u003e\u003cb\u003e10 kV Surge Protection\u003c\/b\u003e\u003cbr\u003eIndustry-leading port surge protection capability.The ports can endure 10 kV surge. The PoE power modules can endure 8 kV surges and non-PoE ones can withstand 6 kV surges, strong protection ability, adaptation to harsh environment. \u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"generic\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eManagement features\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTraffic classification\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARP inspection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch layer\u003c\/td\u003e\n\u003ctd\u003eL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch type\u003c\/td\u003e\n\u003ctd\u003eManaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulticast support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCloud-managed\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePorts \u0026amp; interfaces\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+ module slots quantity\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic switching RJ-45 Ethernet ports quantity\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic switching RJ-45 Ethernet ports type\u003c\/td\u003e\n\u003ctd\u003eGigabit Ethernet (10\/100\/1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB 2.0 ports quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of management ports\u003c\/td\u003e\n\u003ctd\u003e1 pc(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eNetwork\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetworking standards\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1p, IEEE 802.3af, IEEE 802.3ah, IEEE 802.3at, IEEE 802.3az\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of VLANs\u003c\/td\u003e\n\u003ctd\u003e4094\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLAN support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10G support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-negotiation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVirtual LAN features\u003c\/td\u003e\n\u003ctd\u003eIP subnet–based VLAN, Private VLAN, Interface-based VLAN, Protocol-based VLAN, MAC address-based VLAN, Voice VLAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv6 routes\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv4 routes\u003c\/td\u003e\n\u003ctd\u003e8000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIGMP snooping\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGARP VLAN Registration Protocol (GVRP)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv6 multicast entries\u003c\/td\u003e\n\u003ctd\u003e1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv4 multicast entries\u003c\/td\u003e\n\u003ctd\u003e2500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIGMP proxy\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eData transmission\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo frames\u003c\/td\u003e\n\u003ctd\u003e9216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAC address table\u003c\/td\u003e\n\u003ctd\u003e32000 entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching capacity\u003c\/td\u003e\n\u003ctd\u003e176 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumbo frames support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacket buffer memory\u003c\/td\u003e\n\u003ctd\u003e3 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForwarding rate\u003c\/td\u003e\n\u003ctd\u003e132 Mpps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of VLANs\u003c\/td\u003e\n\u003ctd\u003e4094\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulticast Listener Discovery (MLD) snooping\u003c\/td\u003e\n\u003ctd\u003eMLD snooping v1\/v2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eSecurity\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP-MAC-Port binding\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuthentication\u003c\/td\u003e\n\u003ctd\u003eMAC-based authentication, Web-based authentication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity algorithms\u003c\/td\u003e\n\u003ctd\u003eHTTPS, SSH, SSH-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIGMP snooping\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Control List (ACL)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuthentication type\u003c\/td\u003e\n\u003ctd\u003eAAA, IEEE 802.1x, RADIUS, TACACS+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQueue scheduling algorithms\u003c\/td\u003e\n\u003ctd\u003eDRR+SP, SP, WFQ, Weighted Round Robin (WRR), Deficit Round Robin (DRR), WFQ+SP, WRR+SP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Control List (ACL) ingress\u003c\/td\u003e\n\u003ctd\u003e3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccess Control List (ACL) egress\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIGMP proxy\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDHCP features\u003c\/td\u003e\n\u003ctd\u003eDHCP relay, DHCPv6 relay, DHCP server, DHCPv6 server, DHCP snooping, DHCPv6 snooping, DHCP client, DHCPv6 client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eMulticast features\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulticast support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulticast Listener Discovery (MLD) snooping\u003c\/td\u003e\n\u003ctd\u003eMLD snooping v1\/v2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv6 multicast entries\u003c\/td\u003e\n\u003ctd\u003e1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv4 multicast entries\u003c\/td\u003e\n\u003ctd\u003e2500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eProtocols\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGARP VLAN Registration Protocol (GVRP)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting protocols\u003c\/td\u003e\n\u003ctd\u003eRIP, OSPFv3, RIPng, OSPFv2, VRRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv4 \u0026amp; IPv6 features\u003c\/td\u003e\n\u003ctd\u003eIPv6 source address validation improvement (SAVI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eDesign\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack mounting\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStackable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct colour\u003c\/td\u003e\n\u003ctd\u003eGrey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of fans\u003c\/td\u003e\n\u003ctd\u003e1 fan(s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePerformance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor frequency\u003c\/td\u003e\n\u003ctd\u003e1200 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e51.6 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory type\u003c\/td\u003e\n\u003ctd\u003eSDRAM \/ Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal memory\u003c\/td\u003e\n\u003ctd\u003e1000 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash memory\u003c\/td\u003e\n\u003ctd\u003e2000 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMean time between failures (MTBF)\u003c\/td\u003e\n\u003ctd\u003e315000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in processor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStackable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacket buffer memory\u003c\/td\u003e\n\u003ctd\u003e3 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-negotiation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePower\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption (max)\u003c\/td\u003e\n\u003ctd\u003e75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower protection features\u003c\/td\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input voltage\u003c\/td\u003e\n\u003ctd\u003e90 - 264 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input frequency\u003c\/td\u003e\n\u003ctd\u003e47\/63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e\n\u003ctd\u003eAC\/PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePower over Ethernet (PoE)\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower over Ethernet (PoE)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Power over Ethernet (PoE) budget\u003c\/td\u003e\n\u003ctd\u003e1570 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower protection features\u003c\/td\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eOperational conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e0 - 45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (T-T)\u003c\/td\u003e\n\u003ctd\u003e-40 - 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e10 - 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage relative humidity (H-H)\u003c\/td\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eVirtual LAN features\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of VLANs\u003c\/td\u003e\n\u003ctd\u003e4094\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVLAN support\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVirtual LAN features\u003c\/td\u003e\n\u003ctd\u003eIP subnet–based VLAN, Private VLAN, Interface-based VLAN, Protocol-based VLAN, MAC address-based VLAN, Voice VLAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eWeight \u0026amp; dimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e442 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e420 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e43.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePackaging content\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick start guide\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003ePackaging data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage width\u003c\/td\u003e\n\u003ctd\u003e570 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage depth\u003c\/td\u003e\n\u003ctd\u003e565 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage height\u003c\/td\u003e\n\u003ctd\u003e172 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick start guide\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eIPv4 \u0026amp; IPv6 features\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPv4 \u0026amp; IPv6 features\u003c\/td\u003e\n\u003ctd\u003eIPv6 source address validation improvement (SAVI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth colspan=\"2\" class=\"text-left\"\u003eMobile network\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGARP VLAN Registration Protocol (GVRP)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Ruijie Networks","offers":[{"title":"Default Title","offer_id":46408149041287,"sku":"RG-CS83-48GT4XS-PD","price":2691.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0750\/0260\/9799\/files\/WgSvcOnvdEq46ysSu2UlEQ.c-m.jpg?v=1793651782","url":"https:\/\/itclearancecompany.com.au\/products\/ruijie-networks-rg-cs83-48gt4xs-pd-network-switch-managed-l3-gigabit-ethernet-101001000-power-over-ethernet-poe-1u-grey-rg-cs83-48gt4xs-pd","provider":"IT Clearance Company","version":"1.0","type":"link"}